GEORGzer Community moderator
Comentarios
Actividad reciente de GEORGzer
-
That sounds more like an operating error to me. Normally you set a heating-circuit temperature on the boiler (many have those typical turning knobs for that), switch it on and leave that as is. Fro...
- Ver comentario
- Editado
- 0 votos
-
„only the hot water is activated and the radiator boiler does not activate“ You mean hot water like in your bathtub/shower but radiator heating didn‘t work before either?
- Ver comentario
- 0 votos
-
TA1 should be the correct terminal to connect a thermostat. Unless another thermostat was installed before, there should be a bridge cable that has to be removed before connecting the Netatmo Therm...
- Ver comentario
- 0 votos
-
Il n'y a pas de risque de conflit puisque tout ce que fait le Relais est de fermer le circuit entre les fils noirs et gris, ils ne fournissent aucun courant électrique. Ainsi, avoir deux d'entre eu...
- Ver comentario
- Editado
- 0 votos
-
Oui, vous pouvez le faire, il suffit de câbler les fils noirs/gris en parallèle. Original answer since I don’t speak french 😅: Yes you can do that, just wire the black/grey wires in parallel.
- Ver comentario
- Editado
- 0 votos
-
Glad it‘s working now. Polarity of the black/grey wires is not important, they never carry any currency. All that happens when the Thermostat switches on is that those two wires get bridged interna...
- Ver comentario
- 0 votos
-
Hm, without looking up this brand any closer I can say that connecting the black/grey wires to BUS is not correct. You have to connect them where the jumper cable was.
- Ver comentario
- 0 votos
-
Did they come with the base? Are they on the base, so powered on and if so, do they flash red periodically?
- Ver comentario
- 0 votos
-
Sorry to hear that. Maybe they will respond now since the holidays have passed.
- Ver comentario
- 0 votos
-
Manual mentions an „OpenTherm Extension“ but I wasn’t able to obtain more information, sorry.
- Ver comentario
- 0 votos