GEORGzer Community moderator
Commenti
Attività recente di GEORGzer
-
can you post a screenshot of the „manage my home“ screen?
- Visualizza commento
- 0 voti
-
To me it looks like you have every Valve in it‘s own room. Go to settings, „manage my home“ and add/name as many rooms as you need. Then navigate to the individual Valves in the settings, tap on t...
- Visualizza commento
- 0 voti
-
🤔 can you post a screenshot of the app how it os displayed there?
- Visualizza commento
- 0 voti
-
If you put them in the same „room“ in the app, then they will appear and act as a single unit.
- Visualizza commento
- 0 voti
-
well done 👍 Without the boiler model of the OP, it’s hard to tell.
- Visualizza commento
- 0 voti
-
Normally a 3-wire setup contains N, L and one return. L/N is needed to power the old thermostat and when heat is requested, L is send back through the return wire. It should be like that unless i...
- Visualizza commento
- 0 voti
-
You can test your wiring by connecting 1 & 2 together without a Thermostat. If your boiler starts, then the Thermostat could be faulty. If not then the wiring is not correct. Although a 3 wire-setu...
- Visualizza commento
- 0 voti
-
No need to, it‘s a constant calibrating/calculating process. When you do true temperature corrections, they are for the moment to steere the algorithm into the right direction. But it’s not like yo...
- Visualizza commento
- 0 voti
-
There are 6 radiator adapters included (M30x1.5, M30x1.0, M28x1.5, Danfoss RAVL, Danfoss RA, Giacomini) M28x1.0 are sold separately.
- Visualizza commento
- 1 voto
-
This is a classic 230v actuator, therefore you can wire it with the Netatmo Thermostat.
- Visualizza commento
- 0 voti