Thanks, the first screenshot indicates that you have single rooms with only one Valve each in them. On the second screenshot your‘re not changing the Valve‘s room, you‘re editing the room „type“. T...
- Opmerking weergeven
- Bewerkt
- 0 stemmen
-
can you post a screenshot of the „manage my home“ screen?
- Opmerking weergeven
- 0 stemmen
-
To me it looks like you have every Valve in it‘s own room. Go to settings, „manage my home“ and add/name as many rooms as you need. Then navigate to the individual Valves in the settings, tap on t...
- Opmerking weergeven
- 0 stemmen
-
🤔 can you post a screenshot of the app how it os displayed there?
- Opmerking weergeven
- 0 stemmen
-
If you put them in the same „room“ in the app, then they will appear and act as a single unit.
- Opmerking weergeven
- 0 stemmen
-
well done 👍 Without the boiler model of the OP, it’s hard to tell.
- Opmerking weergeven
- 0 stemmen
-
Normally a 3-wire setup contains N, L and one return. L/N is needed to power the old thermostat and when heat is requested, L is send back through the return wire. It should be like that unless i...
- Opmerking weergeven
- 0 stemmen
-
You can test your wiring by connecting 1 & 2 together without a Thermostat. If your boiler starts, then the Thermostat could be faulty. If not then the wiring is not correct. Although a 3 wire-setu...
- Opmerking weergeven
- 0 stemmen
-
No need to, it‘s a constant calibrating/calculating process. When you do true temperature corrections, they are for the moment to steere the algorithm into the right direction. But it’s not like yo...
- Opmerking weergeven
- 0 stemmen
-
There are 6 radiator adapters included (M30x1.5, M30x1.0, M28x1.5, Danfoss RAVL, Danfoss RA, Giacomini) M28x1.0 are sold separately.