If you put them in the same „room“ in the app, then they will appear and act as a single unit.
- View comment
- 0 votes
-
well done 👍 Without the boiler model of the OP, it’s hard to tell.
- View comment
- 0 votes
-
Normally a 3-wire setup contains N, L and one return. L/N is needed to power the old thermostat and when heat is requested, L is send back through the return wire. It should be like that unless i...
- View comment
- 0 votes
-
You can test your wiring by connecting 1 & 2 together without a Thermostat. If your boiler starts, then the Thermostat could be faulty. If not then the wiring is not correct. Although a 3 wire-setu...
- View comment
- 0 votes
-
No need to, it‘s a constant calibrating/calculating process. When you do true temperature corrections, they are for the moment to steere the algorithm into the right direction. But it’s not like yo...
- View comment
- 0 votes
-
There are 6 radiator adapters included (M30x1.5, M30x1.0, M28x1.5, Danfoss RAVL, Danfoss RA, Giacomini) M28x1.0 are sold separately.
- View comment
- 1 vote
-
This is a classic 230v actuator, therefore you can wire it with the Netatmo Thermostat.
- View comment
- 0 votes
-
It can take both, the Netatmo transformers are actually DC. But AC is more common for doorbells.
- View comment
- 0 votes
-
The Doorbell supports: 8-24 VAC & 230 VAC, minimum 8 VA 8VA at 8V are 1A, but the past has shown that like 2A are more recommended.
- View comment
- 1 vote
-
Thermostat and Relais always switch together, so you should be able to wire two different things to them and switch them together at the same time.
- View comment